Intermate Twinax Connection LX T-04 Instrukcja Użytkownika Strona 33

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 81
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 32
A d v a n c e d F u n c t i o n s
I n t e r m a t e L X T - 0 4 33
%P
(Configuration lead-in sequence)
=54,5
(Select Editable Set)
=203,$4A,$7B
(Translate EBCDIC Int. 5 $4A to ASCII $7B)
=206
(Initialize settings)
=205
(Save settings permanently)
%
'54' Is the Parameter number. '5' selects the Editable Set (see
Appendix A).
'203' Is the function number, '$4A' is the EBCDIC International
Set 5 code and '$7B' is the new ASCII value (old ASCII
value is deleted).
'206' and '205' Are also function numbers.
From now on, a left bracket '[' is replaced by '{' in printouts.
You can modify any number of cells in the table by adding lines with function
203 calls.
Note: To edit, Extended Emulation Mode must be entered.
In 4214 emulation, you can edit the Translation Table although you cannot
select ASCII Character Set.
Przeglądanie stron 32
1 2 ... 28 29 30 31 32 33 34 35 36 37 38 ... 80 81